Analysis of the Application of Lead-Steel Structure in Industrial X-ray Radiographic Inspection Rooms
Abstract
With the widespread application of industrial X-ray inspection technology, ensuring the safety and health of operators has become a key issue. Due to its excellent radiation shielding performance, lead-steel structure is widely used in X-ray inspection rooms. This paper analyzes the application of lead-steel structures in industrial X-ray inspection rooms, particularly focusing on their advantages and challenges in radiation protection and monitoring. Firstly, the characteristics of lead-steel structures and their role in X-ray inspection rooms are introduced, emphasizing the necessity of protective design. Then, the basic requirements of radiation protection and monitoring, relevant regulations, and standards are discussed, along with the analysis of radiation monitoring equipment and methods. Finally, through data collection and analysis, the protective effect of lead-steel structures is evaluated, and the experimental results are discussed with suggestions for improvements. The study shows that lead-steel structures can effectively improve radiation protection performance in X-ray inspection rooms, but they still need optimization based on environmental requirements.
References
[2] Hangai, Y., et al. (2021). X-ray radiography inspection of pores of thin aluminum foam during press forming immediately after foaming. Metals, 11(8), 1226. https://doi.org/10.3390/met11081226
[3] Saboonchi, H., Blanchette, D., & Hayes, K. (2021). Advancements in radiographic evaluation through the migration into NDE 4.0. Journal of Nondestructive Evaluation, 40, 1-12. https://doi.org/10.1007/s10921-021-00749-x
[4] Masuch, S., et al. (2022). Applications and development of X-ray inspection techniques in battery cell production. Processes, 11(1), 10. https://doi.org/10.3390/pr11010010
[5] Siryabe, E., et al. (2020). X-ray digital detector array radiology to infer sagging depths in welded assemblies. NDT & E International, 111, 102238. https://doi.org/10.1016/j.ndteint.2020.102238
[6] Chen, M., et al. (2021). Fast-response X-ray detector based on nanocrystalline Ga2O3 thin film prepared at room temperature. Applied Surface Science, 554, 149619. https://doi.org/10.1016/j.apsusc.2021.149619
[7] Wei, J., et al. (2022). Organic room-temperature phosphorescent polymers for efficient X-ray scintillation and imaging. Advanced Photonics, 4(3), 035002. https://doi.org/10.1117/1.AP.4.3.035002
[8] Yamanaka, K., et al. (2021). Quantifying the dislocation structures of additively manufactured Ti–6Al–4V alloys using X-ray diffraction line profile analysis. Additive Manufacturing, 37, 101678. https://doi.org/10.1016/j.addma.2020.101678
[9] Khosravani, M. R., & Reinicke, T. (2020). On the use of X-ray computed tomography in assessment of 3D-printed components. Journal of Nondestructive Evaluation, 39(4), 75. https://doi.org/10.1007/s10921-020-00721-1
[10] Linardatos, D., et al. (2021). On the response of a micro non-destructive testing X-ray detector. Materials, 14(4), 888. https://doi.org/10.3390/ma14040888